DataPanel_MI_QW_PWM
Output service interface function block for PWM output data (Data Mode 2)
Interface
Event Inputs
Name |
Comment |
With |
|---|---|---|
INIT |
Service Initialization |
QI, PARAMS, u8SAMember, Output |
REQ |
Service Request |
QI, OUT |
Event Outputs
Name |
Comment |
With |
|---|---|---|
INITO |
Initialization Confirm |
QO, STATUS |
CNF |
Confirmation of Requested Service |
QO, STATUS |
Input Vars
Name |
Type |
Initial Value |
Comment |
|---|---|---|---|
QI |
BOOL |
Event Input Qualifier |
|
PARAMS |
STRING |
Service Parameters |
|
OUT |
WORD |
Output data to resource |
|
u8SAMember |
USINT |
MI::MI_00 |
Node SA 224..239 |
Output |
DataPanel::io::MI::DQ::DataPanel_MI_DO_S |
Invalid |
Identify the Output DigitalOutput_1A..8B and Input_Power_Port_5..8 |
Output Vars
Name |
Type |
Comment |
|---|---|---|
QO |
BOOL |
Event Output Qualifier |
STATUS |
STRING |
Service Status |