DataPanel_FREQ_SAE_J1939

Frequency/Counter Inputs 7A-8A Status

Interface

Event Inputs

Name

Comment

With

INIT

Service Initialization

QI, u8SAMember

Event Outputs

Name

Comment

With

INITO

Initialization Confirm

QO, STATUS

IND

Indication from Resource

QO, STATUS, Hertz_Count_7A, DutyCycle_SP_7A, Hertz_Count_8A, DutyCycle_SP_8A

Input Vars

Name

Type

Initial Value

Comment

QI

BOOL

Event Input Qualifier

u8SAMember

USINT

MI::MI_00

Node SA 224..239

Output Vars

Name

Type

Comment

QO

BOOL

Event Output Qualifier

STATUS

STRING

Service Status

Hertz_Count_7A

UINT

Frequency (Hz) or Count for Input 7A

DutyCycle_SP_7A

UINT

Duty Cycle or Setpoint for Input 7A

Hertz_Count_8A

UINT

Frequency (Hz) or Count for Input 8A

DutyCycle_SP_8A

UINT

Duty Cycle or Setpoint for Input 8A