DataPanel_AMP_FEEDBACK_SAE_J1939

Amperage Feedback of 1 DataPanel Node

Interface

Event Inputs

Name

Comment

With

INIT

Service Initialization

QI, u8SAMember

Event Outputs

Name

Comment

With

INITO

Initialization Confirm

QO, STATUS

IND

Indication from Resource

QO, STATUS, Current_1A, Current_1B, Current_2A, Current_2B, Current_3A, Current_3B, Current_4A, Current_4B, Current_5A, Current_5B, Current_6A, Current_6B, Current_7A, Current_7B, Current_8A, Current_8B

Input Vars

Name

Type

Initial Value

Comment

QI

BOOL

Event Input Qualifier

u8SAMember

USINT

MI::MI_00

Node SA 224..239

Output Vars

Name

Type

Comment

QO

BOOL

Event Output Qualifier

STATUS

STRING

Service Status

Current_1A

UINT

Current in mA or 0.1A depending on module

Current_1B

UINT

Current_2A

UINT

Current_2B

UINT

Current_3A

UINT

Current_3B

UINT

Current_4A

UINT

Current_4B

UINT

Current_5A

UINT

Current_5B

UINT

Current_6A

UINT

Current_6B

UINT

Current_7A

UINT

Current_7B

UINT

Current_8A

UINT

Current_8B

UINT